Special equipment for PURION water disinfection plant

Operating Power Detection - OPD

UV sensors and their respective monitors are necessary for surveillance of uv plants and more as a standard in modern plants. The OPD was developed for surveillance of uv-plants.
This system observe the uvc-irradiance of the used uv-lamps. The sensors we offer are printed with Carbide Photo-diodes (SiC). The used diodes have a very good sensitivity for the main wavelength between 250 nm and 260 nm. This is also the main wavelength from low-pressure lamps.
The surveillance was designed in kind of a »traffic light«. The device delivers, in combination with the uv sensor, percentage information of the uv-radiation power. The uv monitor is installed after the front side of the control box.

Technical data of sensor
applications drinking water, waste water
material probe body stainless
flanges external G 1/4" thread
diode/sensitivity SIC/230 nm - 320 nm
angle of opening ca. 30°
operating temperature 0° C to + 60° C/100° C for brief periods
pressure resistance 16 bar overpressure to 1 bar sub-atmospheric pressure
electrical connection flanged plug, 5-pole cable

Technical data of surveillance

operating voltage 230 V AC
(110 V AC, 24 V DC or
12 V DC possible)
input signal from SiC-UV sensor

Display

continuous (green LED) at > 70% of starting power
pre alarm (yellow LED) at < 70% of starting power
main alarm (red LED) at < 50% of starting power
red LED flashing no sensor, sensor defect, cable break, measuring amplifier defect
green LED flashing measuring amplifier defect

Monitoring of the life time/Operating Time Counter - OTC

The operating time counter is necessary for surveillance of uv plants, and more as a standard in modern uv plants. The OTC was developed for surveillance of uv plants.
The system works as normal as an operating-hour-counter. After impression of the operating voltage (230 V AC) the counter starts running. On each switch-on the so called »startup« procedure is carried out. In doing so the LEDs red, yellow and green lights one after another each with 1 second. The procedure allows the monitoring of the functioning fo the LEDs. Moreover systematic interruption of the procedure allows resetting of the counter.
The surveillance was designed in kind of a »traffic light«. In the memory of the unit are two time-barriers (tyellow and tred ) to save. Is the effective time t < tyellow, the green LED becomes illuminated. Exceed the effective time these time-barrier, the yellow LED becomes illuminated. If the effective time exceeds the second time-barrier, the red LED becomes illuminated. The uv monitor is installed after the front side of the control box.

Technical data of surveillance for life time
operating voltage 230 V AC
(110 V AC, 24 V DC or 12 V DC possible
special function counter can be resetted after replacement of the lamp

Display

continuous (green LED) < 95% to guaranteed life time
pre alarm (yellow LED) > 95% to guaranteed life time
main alarm (red LED) guaranteed life time is over